• Liebert POWERBANK

    0 out of 5

    True on-line double conversion,Generator compatibility,Inbuilt isolation,Inbuilt static bypass,Extended autonomy up to 2 hours,

    Type Online UPS
    Capacity 6kVA/4.2kW
    Nominal Input Voltage(AC) 230 VAC
    AC Voltage Regulation 220 VAC
    Waveform Pure Sinewave
    DC Voltage 192 VDC,2Hr Backup
    Dimension, D X W X H (mm) 425X730X550
    Transfer Time
    Power Management
  • Offline Highend UPS 7.5KVA

    0 out of 5

    IGBT-Microcontroller Based (DSP Technology ),Full featured LCD Display,Wide Input Range,Fast Changeover,Advanced MSP charger,No humming on both charging & inverter mode,Short circuit protection ideal for home and Industrial applications

    Type Offline ups
    Capacity 7.5KVA /6000W
    Nominal Input Voltage(AC) 110VAC – 290VAC
    AC Voltage Regulation 230VAC
    Waveform SineWave
    DC Voltage 72VDC,96VDC,120VDC
    Dimension, D X W X H (mm)
    Transfer Time 12 msec
    Power Management
  • Libert ITON CX 2000 VA

    0 out of 5

    Ideal for PCs and Sesitive electronic eqipment with AVR and Overload, discharge, and overcharge protection,Smart RS232/USB interface forpower management,Cold start function,Generator compatible

    Type line-interactive UPS
    Capacity 2000 VA/1200 Watt.
    Nominal Input Voltage(AC) 220/230 VAC
    AC Voltage Regulation ±10%
    Waveform Simulated Sine Wave
    DC Voltage 12 V/9Ah x 1 – Built-IN
    Dimension, D X W X H (mm) 369 X 141 X 160
    Transfer Time Typical 4-8 msec
    Power Management Smart RS232/USB
  • Liebert® APM

    0 out of 5

    The Flexpower Technology for mission critical applications,Standalone static bypass module,FlexPower core hardware assemblies,Distributed Controls,Expand for capacity or redundancy in 18kW increments within a single cabinet,Intelligent Server Power Manager,Modular Power Distribution Module,Hot Swappable circuit Breaker,Built-in distribution switch and
    manual maintenance bypass,Standalone static bypass module,Hot swappable module,Unity Power Factor*; 18 kW module.

    Type Liebert® APM
    Capacity 18KVA,36KVA,54KVA,72KVA,90KVA
    Nominal Input Voltage(AC) 380/400/415Vac, 3-phase and 4 -wire
    Nominal Ouput Voltage(AC) 380/400/415Vac, 3-phase and 4-wire
    Waveform Pure Sine Wave
    DC Voltage Selected on Site
    Dimension, D X W X H (mm) 1100 x600 x 2000
    Transfer Time NA
    Power Management Centralized Monitoring And Control For the IT Environment.
  • Liebert® Hipulse-E

    0 out of 5

    AC Power for Business-Critical Continuity,Utility-Friendly & Generator-Friendly,Horizontal Xpandability & Redundancy,Multi Bus Compatibility,Flexi Power Walk-In,Temperature Compensated Battery Charging,Compact Active & Passive Footprints,Other Remote Communications,Local Communications,1+N Configuration with Distributed bypass System , Hot Stand-by Configuration.

    Type Liebert® Hipulse-E
    Capacity 500KVA , 600KVA , 800KVA
    Nominal Input Voltage(AC) 380/400/415* (400V: nominal) 3-phase, 3-wire (OR) 380/400/415* (400V: nominal) 3-phase +N, 4-wire
    Nominal Ouput Voltage(AC) 380/400/415* (400V: nominal) 3-phase, 4-w
    Waveform Pure Sine Wave
    DC Voltage 480V , 396V
    Dimension, D X W X H (mm) 1000×2460-4410 x4200-5050
    Applications Information Technology ,Telecommunication ,Industrial Automation,Transport Automation,Banking, Insurance and Financial Services,Software Development Houses / Software Technology Parks (STP) , Building Automation , Medical Diagnostics , Satellite
    Power Management RS-232 & RS-485 ports and through HiroLink, IGMNet protocols. These provide you with the opportunity to integrate the communication
    system with our High Performance Air Conditioning (HPAC) systems. Other than utilizing RS-232 port for remote communication, it can also be used for local downloading of data for the service engineers, while the RS-485 port can be utilized to have remote communications of myriad applications.
  • Liebert® HIPULSE-EX

    0 out of 5

    Efficient, Flexible Power Optimized For Medium Size UPS Applications.Rated at 0.8 output power factor to deliver more real power , Handle Leading power factor loads without KW de-rating under specified conditions , High overload capability of static
    bypass,Built-in maintenance bypass (Single and 1+N Models) , Input Isolation Transformer , Protection Degree (IP) for
    Hipulse-EXTM Enclosure , DC Ground Fault Indication , Top Cable Entry , Power Walk-in for 1+N System , LBS , TVSS.

     

    Type Liebert® HIPULSE-EX
    Capacity 80KVA,120KVA,160KVA,200KVA
    Nominal Input Voltage(AC) 380/400/415Vac 3P-4Wire
    Nominal Ouput Voltage(AC) 380/400/415V – 3 Phase with Neutral
    Waveform Pure Sine Wave
    DC Voltage Selected on Site
    Dimension, D X W X H (mm) 875×900-1250×1900
    Applications Information Technology ,Telecommunication ,Industrial Automation,Transport Automation,Banking, Insurance and Financial Services,Software Development Houses / Software Technology Parks (STP) , Building Automation , Medical Diagnostics , Satellite
    Power Management OpenComms™ Web Card , Relay Contact Card , RS-232 port for local downloading of data, while the RS-485 port can be utilized for a variety remote communications application.
  • Liebert® NX

    0 out of 5

    Transformer-free. High E iciency , Scalable On-line UPS .Overall e iciency up to 99.3% in Intelligent ECO mode,Supports smart parallel function,Input power factor >0.99,Input current distortion (THDi) <3%,Excellent generator adaptability , Widest input voltage & frequency range , Battery ground fault detection , Strong 0 .9 output PF loading capacity , Easy Installation , Maintenance-Free .

    Type Liebert® NX
    Capacity 250KVA , 300KVA , 400KVA , 500KVA , 600KVA , 800KVA , 1000KVA
    Nominal Input Voltage(AC) 380/400/415Vac, 3-phase 4-wire
    Nominal Ouput Voltage(AC) 380/400/415Vac, 3-phase 4-wire
    Waveform Pure Sine Wave
    DC Voltage 38 to 48 no. for 250-500 ; 40 no. for 600-1000
    Dimension, D X W X H (mm) 900×1200-3600 x 1900
    Applications IT Loads , Data Centers , Manufacturing Industries , Process Industries , Telecom.
    Power Management Centralized Monitoring And Control For the IT Environment.